Part Information:
 

 
Part Number: 193-2821-0XX**
Description: .050 centerline, 28 awg High Temperature Low Smoke / Halogen Free, Flame Retardant Zip Cable
Family: Zero Halogen

 
Outline Drawing
 
Introduction

 

Spectra-Strip's high temperature (+150° C) Low Smoke / Halogen Free Zip cable is extruded with a very flame retardant, non-halogenated copolymer, ideal for use in closed environments where ventilation is poor, such as subways, elevators, and ships. It is designed to reduce the generation of toxic and corrosive gases that are emitted from typical PVC insulated cables during combustion. These gases can injure personnel enclosed within these confined spaces and can also corrode delicate components within electronic equipment. Many well-documented cases exist of extensive injury and death occurring as a result of fires involving these PVC generated toxic gasses, e.g., the London Subway fire, the Beverly Hills Supperclub fire, the Dusseldorf Airport fire, and the HMS Sheffield sinking. (Click here for good background reading)


 

Features/Benefits
  • 9 through 64 conductors, precision extruded on .050" centerlines
  • -65°C to +150°C
  • Compatible with IDC connectors
  • Reduced generation of toxic gases during combustion
  • Highly flame retardant (limiting oxygen index 46%)

 
Specifications
Physical

Conductors

28 AWG 7/36 strand tinned copper

Color

Amber with number one conductor colored red

Insulation

.010" copolymer

Cable Thickness:

.033" ± .002"

Conductor spacing:

.050" ± .003"

UL Style

20657

Temperature Rating

-65° C to 150° C

 

Electrical

Impedance

110 ohms nom single ended

Capacitance

13pF / ft @ 1 MHz, single ended

Propagation Delay

1.4 ns / ft nom

Voltage Rating

300 V

Current Rating

1.0 A @ 10° C above ambient


 
Toxicity and Corrosivity Results

 

Property

Standard

Requirement

Results

Flame and Fire Propagation

IEC 332-1

Pass

Pass

Smoke Density

ASTM E 662

 

 

IEC 1034-1
and �2

DS < 250 flaming and non flaming modes

 

Pass

Flaming 0.62/0.75, non-flaming 0.24/16.2
 

 

Pass

Toxicity of Fire Gasses

AIS 1000.001

HF < 100

HCI < 150

HCN <150

S02 +H2 S <100

CO <3500

NO + N02 <100

HF <100

HCI <150

HCN<150

S02 +H2 S <100

CO <3500

NO + N02 <100

Corrosivity of Fire Gasses

IEC 754-2

PH >4, conductivity <100uS / cm

PH 4.5, conductivity none

UV Resistance

IEC 68-2-5

No discoloration or stickness

NA

Radiation Resistance

IEC 544-2-5

Index >5.7

NA

Acid Gas Generation

MIL-C- 24643

 

0.47%

Smoke Index

NES-711

 

5.3

Toxicity Index

NES-713

 

1.4

Limiting Oxygen Index

ASTM D 2863

 

46

Notes On Standards:

  1. ASTM E662: STANDARD TEST METHOD FOR SPECIFIC OPTICAL DENSITY OF SMOKE
  2. ATS 1000.001: AIRBUS INDUSTRY TECHNICAL SPECIFICATION, FIRE TEST SPECIFICATION
  3. IEC 68-2-5 SIMULATED SOLAR RADIATION AT GROUND LEVEL
  4. IEC 332-1: TESTS ON ELECTRIC CABLES UNDER FIRE CONDITIONS
  5. IEC 754-2: TEST ON GASES EVOLVED DURING COMBUSTION OF ELECTRIC CABLES
  6. IEC 544-2-4: GUIDE FOR DETERMINING THE EFFECTS OF IONIZING RADIATION ON INSULATING MATERIALS.
  7. IEC 1034-1-2: TEST FOR THE MEASUREMENT OF SMOKE DENSITY OF ELECTRIC CABLES BURNING UNDER DEFINED CONDITIONS

 
Ordering Information